NORPEN.DLL SYSTEM.INI Configuration Example
To configure the 6300 Computer with the default values, place the following
entries into SYSTEM.INI:
SYSTEM.INI:
[Pen Driver]
PortAddr=520
IrqLevel=12
BaseClock=0
UseNV=1
PointsPerSecond=50
cxRawWidth=4500
cyRawWidth=3000
wDistinctWidth=3500
wDistinctHeight=3045
wOffsetX=0
wOffsetY=0
PenOrientation=2
FlipX=0
[Display Driver]
DisplayOrientation=1
DisplayColumns=320
DisplayRows=480
Pen Calibration
PENALIGN.EXE is a Windows penĆcalibration utility, and takes no parameters.
There are two screens.  The first asks you to tap three times in several marked
locations on the screen.  The second asks you to overlay (match) the cursor and
the pen position.
Alternatively, you can set the calibration by adjusting the calibration entries in
SYSTEM.INI.  This is a fairly tedious approach that requires an understanding
of digitizer orientation and digitizer coordinate systems.  To enable the use of
these calibration entries in SYSTEM.INI, set the 
UseNV
 setting to 0.