Intermec 5020 User Guide
Chapter 7 — Trakker Antares Terminals
80
Data Collection Browser User’s Guide
6
Select the FileCopy tab.
7
In the PC Filename and Path box, type:
C:\PROGRAMFILES\INTERMEC\DCBROWSER\CLIENT\TRAKKER\
DCBT24.BIN
DCBT24.BIN
8
In the Terminal Filename and Path box, type:
C:DCBT24.BIN
9
Choose Download. The dcBrowser client is downloaded to your
terminal.
terminal.
Configuring Your Trakker Antares Terminals
Before the Trakker Antares terminal can communicate with the dcBrowser
gateway, you must set the host IP address or the controller IP address to the
dcBrowser gateway IP address. You must then set the network port to 4055
for TCP/IP terminals or 05555 for UDP Plus terminals.
gateway, you must set the host IP address or the controller IP address to the
dcBrowser gateway IP address. You must then set the network port to 4055
for TCP/IP terminals or 05555 for UDP Plus terminals.
To configure the network port
1
On your terminal, access the TRAKKER Antares 2400 Menu System by
pressing ) y 2 4 8 or by scanning this bar code:
pressing ) y 2 4 8 or by scanning this bar code:
TRAKKER Antares 2400 Menu System
*..-.*
2
From the Main Menu, choose Configuration Menu >
Communications Menu > Primary Network. The Primary Network
screen appears.
Communications Menu > Primary Network. The Primary Network
screen appears.
3
Set the Activate field to 2.4 GHz RF, Ethernet, or 802.11b.
Note: If your terminal has a Left Enter key (y), you must use it when
entering the key sequences in Step 1; otherwise, just use the ; key.
entering the key sequences in Step 1; otherwise, just use the ; key.
TCP/IP
UDP Plus
PRIMARY NETWORK
Activate:
Disabled
Host IP Addr:
0.0.0.0
Terminal IP Address:
0.0.0.0
OK
CANCEL
PRIMARY NETWORK
Activate:
Disabled
Controller IP Addr:
0.0.0.0
Terminal IP Address:
0.0.0.0
OK
CANCEL