3-6.Wiring Instructions
 
 
General precautions on wiring
1)  Before  wiring,  confirm  the  rated  voltage  of 
the  unit  as  shown  on  its  nameplate,  then 
carry  out  the  wiring  closely  following  the 
wiring diagram.
2)Provide a power outlet to be used exclusively 
for each unit, with a power supply disconnect 
and 
circuit 
breaker 
for 
overcurrent 
p
r
o
t
e
c
t
i
o
n
provided in the excusive line.
3)To  prevent  possible  hazard  due  to  insulation 
failure, the unit must be grounded.
4)Each  wiring  connection  must  be  done  tightly 
and  in  accordance  with  the  wiring  system 
diagram(Fig.17a,
      Fig.17b  and  Fig.17c).Wrong  wiring  may  cause 
t
h
e
unit to misoperate or become damaged.
5)Do  not  allow  wiring  to  touch  the  refrigerant 
t
u
b
i
n
g
,
compressor, or any moving parts of the fan.
6)Unauthorized  changes  in  the    internal  wiring 
can  be  very  dangerous.  The  manufacturer  will 
accept  no  responsibility  for  any  damage  or 
misoperation  that  occurs  as  a  result  of  such 
unauthorized changes.
7)Special electrical wires and connection cables 
are  used  for  this  air-conditioner  which  can 
be  supplied  by  the  local  distributor,  and 
cannot  be  replaced  by  other  type  wires  or 
cables.
Fig.15
Frame
Right tubing
outlet
Fig.16
Fig.14
Frame
Left  tubing
outlet
1
2
3
4
5
1
2
3
4
5
2
YZW 3×1.5mm
INDOOR
UNIT
OUTDOOR
UNIT
Fig.17a
( F o r c o o l o n l y t y p e s y s t e m )
1
2
3
4
5
1
2
3
4
5
2
YZW 5×1.5mm
INDOOR
UNIT
OUTDOOR
UNIT
Fig.17b
( F o r h e a t p u m p  t y p e s y s t e m )
1
2
3
4
1
2
3
4
2
2
YZW 3×2mm +1×1mm
INDOOR
UNIT
OUTDOOR
UNIT
F ig.1 7c
( F o r h e a t p u m p  f r e n q u e n c y t y p e s y s t e m )