Epson 1080 Installation Instruction
4
Selecting Projector Settings
1. If the projector is ceiling-mounted or set up for rear-screen projection, you need to
reorient the image. Press the
Menu
button on the Epson remote control and open the
Settings
menu. Select
Projection
and then select the projector’s mounting position.
Press the
Menu
button when done to exit the menu system.
2. Press the
Aspect
button and select
Normal
as the aspect ratio.
3. Press the
Color Mode
button and select
HD
as the color mode.
Note: This sets the brightness, contrast, and color settings to 0, Skin Tone to 3, Absolute Color
Temperature to 7500K, lamp Brightness Control to High, and Auto Iris to Off.
Temperature to 7500K, lamp Brightness Control to High, and Auto Iris to Off.
4. Press the
Gamma
button and select
2.2
as the gamma setting.
5. Press the
Menu
button, open the
Image
menu, and select
Sharpness
.
If you see this screen, highlight
Standard
and press the
Select
button:
Change the
Sharpness
setting to
-3
.
6. Press the E
SC
button to return to the main menu. Open the
Signal
menu and then
adjust the following settings:
■
Set
Output Scaling
to
100%
.
■
Set
EPSON Super White
to
Off
.
■
Set
HDMI Video Range
to
Normal
.
7. Press the
Menu
button when done to exit the menu system.
If you see this screen,
select Standard