Configure System Information 
74
M4100 Series Managed Switch 
7. 
Select System > Services > UDP RelayUDP Relay Global Configuration
8. 
Use Admin Mode to enable or disable the UDP Relay on the switch. 
The default value is Disable.
9. 
Use Server Address to specify the UDP relay server address in x.x.x.x format.
10. 
Use UDP Port to specify the UDP Destination Port. These ports are supported:
DefaultSet. Relay UDP port 0 packets. This is specified if no UDP port is selected 
when you are creating the Relay server.
dhcp. Relay DHCP UDP port 67 packets.
domain. Relay DNS UDP port 53 packets.
isakmp. Relay ISAKMP UDP port 500 packets.
mobile-ip. Relay Mobile IP UDP port 434 packets.
nameserver. Relay IEN-116 Name Service UDP port 42 packets.
netbios-dgm. Relay NetBIOS datagram server UDP port 138 packets.
netbios-ns. Relay NetBIOS name server UDP port 137 packets.
ntp. Relay Network Time protocol UDP port 123 packets.
pim-auto-rp. Relay PIM auto RP UDP port 496 packets.
rip. Relay RIP UDP port 520 packets.
tacacs. Relay TACACS UDP port 49 packet.
tftp. Relay TFTP UDP port 69 packets.
time. Relay time service UDP port 37 packets.
Other. If this option is selected, the UDP Port Other Value is enabled. This option 
permits you to enter your own UDP port in UDP Port Other Value.
11. 
Use UDP Port Other Value to specify a UDP Destination Port that lies between 0 and 
65535.
12. 
To create an entry in UDP Relay Table with the specified configuration, click the ADD button.
13. 
To remove all entries or a specified one from the UDP Relay Table, click the DELETE 
button.
The Hit Count field displays the number of UDP packets hitting the UDP port.