Netgear M4100-50-POE (FSM7250Pv1h1) - 48‐port FE + 2 GE Combo L2 Managed PoE Switch User Manual

Page of 446
Configure System Information 
76
M4100 Series Managed Switch 
rip. Relay RIP UDP port 520 packets.
tacacs. Relay TACACS UDP port 49 packet.
tftp. Relay TFTP UDP port 69 packets.
time. Relay time service UDP port 37 packets.
Other. If this option is selected, the UDP Port Other Value is enabled. This option 
permits you to enter your own UDP port in UDP Port Other Value.
11. 
Use UDP Port Other Value to specify UDP Destination Port that lies between 0 and 65535.
12. 
Use Discard to enable or disable dropping of matched packets. 
Enable can be selected only when you enter 0.0.0.0 as the IP address. Discard mode can 
be set to Disable when you add a new entry with a non-zero IP address.
13. 
To create an entry in the UDP Relay Table with the specified configuration, click the ADD 
button.
14. 
To remove all entries or a specified one from the UDP Relay Interface Configuration Table, 
click the DELETE button.
The Hit Count field displays the number of UDP packets hitting the UDP port.
Configure the Basic PoE Settings
To display the Basic PoE Configuration:
1. 
Prepare your computer with a static IP address in the 169.254.100.0 subnet, for 
example, 169.254.100.201.
2. 
Connect an Ethernet cable from an Ethernet port on your computer to an Ethernet port on 
the switch.
3. 
Launch a web browser.
4. 
Enter the IP address of the switch in the web browser address field.
The default IP address of the switch is 169.254.100.100. 
The Login screen displays.
5. 
Enter the user name and password. 
The default admin user name is admin and the default admin password is blank, that is, 
do not enter a password.
6. 
Click the Login button. 
The web management interface menu displays.