Xerox Paris, a document system Support & Software User Guide

Page of 245
Chapter 2 
 
 
80
 
The Paris Spooler Technical Manual 
Windows 3.0 support of UART 
Windows 3.0 does not support the advanced first-in first-out (FIFO) buffer feature 
of the 16550A UART. It supports the 16550 and 16550A as a standard 8250 
UART. 
Identifying the UART chip in your PC 
The Microsoft Diagnostic utility (MSD) supplied with MS-DOS will easily allow 
you to identify the various components of your PC, including the UART chip.  
MSD is run from the DOS prompt simply by typing MSD. The option for COM 
ports will display all details including which UART chip is being used.  
If you find that you have an older 8250 or 16450 UART, you should check with 
your PC dealer about upgrading your I/O board to one with a 16550A UART. 
The information on the following pages is for the Cybercom.drv high speed 
(16550AF) Windows serial port driver from Cybersoft Corp.  This driver allows 
Windows to take full advantage of the 16550 UART chip.