Xerox DocuTech 6100 Production Publisher User Guide

Page of 168
Solutions in Alphabetical Order 
 
DT6180 HandyBook                                                                                                                   
79 
get caught.  
11.  To the left of the ground strap attachment bolt, about 178 mm (7 inches) closer to the floor, you 
should see a red, orange, and brown wire leading to a black plastic block mounted on a metal 
bracket. The plastic block, with small white letters on it, is the detector.  
 
 
12.  About 254 mm (10 inches) left of the detector, under a long black metal bracket, is a round bulb-like 
object. The object is about 10 mm (3/8 inch) in diameter, facing the surface you have just cleaned. 
This is the Q1218 Sensor, and should be cleaned as well.  
 
 
 
 
Q1221 Set Path Sensor:  
13.  Using the Q1218 sensor as a reference point, look about 38 mm (1 1/2 inch) closer to the front of 
the machine. You should see the round sensor for Q1221 pointing straight up.  
14.  Put your finger on the Sensor and move your head to the left of the big black bracket so you can 
see your finger on the Sensor again.  
 
 
15.  Clean the Sensor.