Cisco Cisco Unified MeetingPlace Audio Server Maintenance Manual

Page of 349
5-22
Cisco MeetingPlace Audio Server 5.2 Customer Engineering Guide (for Cisco MeetingPlace 8112)
OL-
Chapter 5      Repairing and Maintaining the 8112 Server
  Replacing the CPU
Figure 5-16 Installing the CPU Card and Transition Module
Step 2
Holding the CPU card by the ejector levers, partially insert the CPU card into the slot, about half way.
Step 3
Verify that the CPU card is properly seated in the guides on the top and bottom. If not, remove the CPU 
card and try again.
Step 4
Pushing gently and firmly on the CPU card’s face plate, slide the CPU card into the slot until you 
encounter significant resistance. At this point, the ejector levers should be in contact with the chassis 
rails so they grab when pushed inward.
Step 5
Use the ejector levers to lock the CPU card in the slot by pushing the ejector levers toward one another 
until they are in the locked position. See 
.
Step 6
Secure the CPU card by tightening the captive screws on the right and left sides of the panel. See 
Step 7
Verify that any empty slots have covers on them.
Warning
An empty slot that is uncovered can result in a destructive hardware failure.
Step 8
Attach the power cable to the back of the server.
Step 9
Power up the server. Refer to the 
Removing the old CPU transition module
Step 1
Verify all steps in the 
 have been completed.
Step 2
Locate the CPU transition module in slot 7 in the back of the server.
Step 3
With a screwdriver, loosen the CPU transition module’s captive screws at the top and bottom of the panel. 
See 
.