Chapter 3      Installing the 8112 Server
  Connecting the system cables
(For all mixed configurations) E1, T1 PRI, and IP configurations all use Multi Access Blades. The 
server is shipped with the necessary number of Multi Access Blades. The number of telephony 
cables shipped with the system depends on the number of ports being activated. You need one 
telephony cable for every 30 ports in an E1 system and one telephony cable for every 23 ports in a 
T1 PRI system.
(For T1 CAS/IP configurations only) The server is shipped with the necessary number of T1 Smart 
Blades. Each T1 Smart Blade transition module in the back of the server has connectors for four 
trunk lines. The number of telephony cables shipped with the system depends on the number of ports 
being activated. You need one telephony cable for every 24 ports in a T1 CAS system. No breakout 
box is needed for this configuration.
(For E1/IP and T1 PRI/IP configurations only) The server is shipped with one or two breakout boxes 
and cables, depending on the configuration. The necessary number of trunk card interface cable 
assemblies (50-pin Amphenol cables) is also shipped. These connect the breakout boxes to the Multi 
Access Blade transition modules.
For the non-IP portion of the mixed system:
the T1 Smart Blade transition modules begin in slot 1 on the right and move to the left (for T1 
CAS/IP configurations)
the Multi Access Blade transition modules begin in slot 1 on the right and move to the left (for E1/IP 
and T1 PRI/IP configurations)
For the IP portion of the mixed system:
the Multi Access Blade transition modules begin in slot 16 on the left and move to the right
the Smart Blades begin after the last Multi Access Blade and do not have any cables connected to 
them
E1/IP or T1 PRI/IP system
To connect the telephony cables in a E1/IP or T1 PRI/IP system, follow these steps:
Step 1
Locate the following items:
IP LAN cables
E1 or T1 PRI telephony cables
breakout box
trunk card interface cable assemblies (50-pin Amphenol cables)
Step 2
Plug the IP LAN cable into the customer-supplied RJ-48c socket.
Step 3
Plug the other end of the IP LAN cable into the Ethernet 1 connector on the Multi Access Blade.
Step 4
Repeat steps 2 and 3 if you have two Multi Access Blades being used for the IP configuration.
Step 5
Depending on the configuration of your E1 or T1 PRI system, follow the steps in one of the following 
sections to connect the E1 or T1 PRI telephony cables: