  Understanding the 8106 server and its components
Understanding the 8106 server’s LEDs
The 8106 server has three types of LEDs as described in 
Refer to 
 to locate the 8106 server’s LEDs.
Figure 2-2
Location of the 8106 Server’s LEDs
Table 2-4
Description of the 8106 Server’s LEDs
Component
LED Color
Meaning
Fan assembly
none
red
fan assembly is working properly or is not properly 
inserted
fan assembly is not working properly
Power supply 
units
green on both
red on both
none on both
green on one; red 
on other
green on one; 
none on other
red on one; none 
on other
power supply units are working properly
neither power supply unit is working properly. Shut 
off the server as soon as possible and remove all 
cards, the floppy drive and CD-ROM drive housing 
unit, and the disk drives
either the server is powered off or the power supply 
units are not properly inserted
one power supply unit is working properly and the 
other is either bad or not properly inserted
one power supply unit is working properly and the 
other is either bad or not properly inserted
one power supply unit is bad and the other is not 
properly inserted
Disk drives
green
none
server is accessing the disk drive
server is not accessing the disk drive