  Environmental requirements
MeetingPlace draws a maximum of 250 watts of power and produces a maximum of 1364 BTU/hour.
T1 digital trunk requirements
T1 Smart Blades support digital connections to a PBX system or to a PSTN. The framing for the digital 
lines can be either extended superframe (ESF) or D4. The digital lines can use either B8ZS coding or 
jammed bit.
Note
We strongly recommend using ESF framing and B8ZS coding. Using D4 framing or jammed bit coding 
may produce unsatisfactory service.
Warning
Supplemental earth grounding is required at all times. This supplemental grounding consists of a 
grounding cable attached to supplemental ground lugs on the back of the 8106 server chassis and is 
permanently connected to an earth ground point at the other end via an appropriate facilities 
grounding terminal.
Shielded cables must be used, and the shield must be electrically terminated at the back of the 8106 
server. MeetingPlace also supports fractional T1 services and has complete flexibility to activate any or 
all ports on a span.
MeetingPlace can use dialed number information to connect the caller directly to a meeting or to 
determine the MeetingPlace services to which the caller has access.
MeetingPlace can also be configured to support devices where the T1 trunk does not provide any 
signaling and is always off-hook. This is used in applications where a clear channel connection is 
required.
Table 3-1
Power Requirements by Country
Country
Clearance
Power
Socket
USA
Canada
1.5 inches of clearance 
in front and back of 
server; 
0.5 inches of clearance 
on top and bottom and 
on right and left
115 VAC
NEMA 5-15R 
socket-outlet installed 
within 8 feet of the unit
Hong Kong
European Union
3.8 cm of clearance in 
front and back of server; 
1.25 cm of clearance on 
top and bottom and on 
right and left
240 VAC
BS-1363 socket-outlet 
installed within 2 
meters of the unit
Japan
3.8 cm of clearance in 
front and back of server; 
1.25 cm of clearance on 
top and bottom and on 
right and left
100 VAC (50Hz for East 
Japan; 60 Hz for West 
Japan)
NEMA 5-15R 
socket-outlet installed 
within 2 meters of unit