Cisco Cisco Unified MeetingPlace Audio Server Release Notes

Page of 15
Release Note, Cisco MeetingServer 5.1.1 
 
Page 4 of 13 
78-16459-01
                        Cisco Systems  
Revision Date: 3/11/05 
 
For information about estimating conversion time, see the PCI to M3 Conversion Guide (part number 
0520-0031-01). 
Note: The M3 system must be initialized before conversion. Existing 5.1 user/group/conference/voice 
data will be lost. See the PCI to M3 Conversion Guide (part number 0520-0031-01) for instructions on 
how to properly initialize a system. 
 
7  Bugs Fixed in MeetingServer 5.1.1  
CR20162 – Major alarm: Database server too many tasks 
Communications problems prevent a gateway from logging out of the MeetingPlace database server 
properly, causing the server to raise alarms about stale connections. 
CR20267 – Downgraded minor alarm for “0x5244e - DB server connected task not 
current” to a warning 
Minor alarm for “0x5244e - DB server connected task not current” is caused by a harmless race 
condition.  
01/23 07:33:54 INFO 0x52455 0/9, "dbcurr.cc", 175 (0x5, 0, 0x3f33, 0) 
      DB server unable to put currency, status 5, dbn 0 
01/23 07:33:54 MIN 0x5244e 0/9, "dbtasks.cc", 614 (0, 0, 0, 0) 
      DB server connected task not current code 0  
CR20537 – User name with blank characters cannot be used to do conversion 
When asked for a user name to use for conversion, and a user name is entered with spaces in the middle, 
the conversion won’t understand it and unrelated errors are returned. 
CR20623 – Outdial users are treated as guest in lecture-style meeting 
Users with the Speaker permissions are treated as guest users when they attend a lecture-style meeting 
through outdial. Users with Speaker permissions who are outdialed are started in the waiting room, and 
not in the main room where they’re supposed to be placed. If they join the meeting by dialing into the 
MeetingPlace system, they are correctly put into the main room with no issues.  
CR20694 – Dataconf parts cannot enter meeting when access ports equals zero 
The number of access ports determines how many users can join meetings. On a ‘Web start” system, 
however, the access port license count equals 0. Access needs to be based on the access port count and/or 
data conf count. 
CR20702 – No remote server outdial for multiserver meeting 
Outdial to remote server doesn't happen for multiserver meetings. Memory error indication in the exlog: 
02/24 17:48:25 MIN  0x20073  0/5, "csconfrec.cc", 4814 (0xc, 0, 0, 0) 
                    Error allocating part record. Err = 12 
02/24 17:48:25 WARN 0xc      0/5, "../../libcm/export/", 202 (0x1, 0x699974, 
0x699974, 0x3c) 
                    Not enough memory  (ENOMEM) 
CR20742 – Minor alarm (90077) 
Received minor alarm due to harmless race condition: 
2/27/2003 8:16 AM Server[0] Code[90077] Severity[Minor] Count[ 1] 
(EvtAreadComplete)Buffer state not readfromdisk, port=1d4, buf=5 
Demoted to a Warning