Cisco Cisco Videoscape Voyager Vantage 3.2 User Guide

Page of 204
29
   
VOD Error Logs
VODCAT Initialization
Note:
 Vodcat module needs the Streamer Manufacturer ID to initialize the corresponding Stream Controller and in turn 
that decides the type of Stream Control protocol to be used. This information should be configured in the /rtn/config.ini. 
If it is not available then vod playback module uses the default one which is Seachange.
DLOG|SPM_VODCTLG|ERROR|pIniConfig was not created
Reason
Failed to access the config.ini file.
Note:
 This would result in the user seeing the “The catalog that you have attempted to access does not appear to be 
configured correctly, please contact Rogers Support at 1-888-Rogers-1 (7643771). Error code: #835MC” error. Check 
if there are any BFS related errors.
DLOG|SPM_VODCTLG|ERROR|Vod Diagnostics Init failed
Reason
Creation of diag file failed. Diagnostics info will not be available.
Note:
 Check for any filesystem related errors. The vod diagnostics file is created at /tmp/vod-diag.txt.
DLOG|SPM_VODCTLG|ERROR|"[vod.cpp][vod_system_init][980] Unable to set the OnDemandSystem 
properties in the VodCatManager
Reason
Failed to set the OnDemandSystem settings to the VodCatManager. If the provided input is NULL then it results in this 
error.
Note:
 This would result in the user seeing the “The catalog that you have attempted to access does not appear to be 
configured correctly, please contact Rogers Support at 1-888-Rogers-1 (7643771). Error code: #835MC” error.
DLOG|SPM_VODCTLG, DLOGL_ERROR, [ parseNpsFile][271] tini_create() failed %d || nps.ini file does not 
exist
Reason
The nps.ini file is not available for extracting the operating mode information.
Note:
 This would result in the user seeing the “The catalog that you have attempted to access does not appear to be 
configured correctly, please contact Rogers Support at 1-888-Rogers-1 (7643771). Error code: #835MC” error. Check 
if there are any BFS related errors.
DLOG|SPM_VODCTLG, DLOGL_ERROR, [vod.cpp] parseNpsFile][290] OperatingMode is not in two way
Reason
Box is not in two way. VOD doesn’t get initialized until box is in two-way.
Note:
 The STB is in not Interactive mode. This is mandatory requirement for the vod module to function since it needs to 
communicate to an external vod catalogue server for fetching the catalogues.This would result in the user seeing the 
“The catalog that you have attempted to access does not appear to be configured correctly, please contact Rogers 
Support at 1-888-Rogers-1 (7643771). Error code: #835MC” error.