Cisco Cisco Gigabit Ethernet Switch Module (CGESM) for HP Technical References

Page of 742
   
A-7
Cisco Gigabit Ethernet Switch Module for the HP p-Class BladeSystem Command Reference Guide
380265-002
Appendix A      CGESM Switch Boot Loader Commands
dir
dir
Use the dir boot loader command to display a list of files and directories on the specified file system.
dir filesystem:/file-url ...
Syntax Description
Command Modes
Boot loader
Command History
Usage Guidelines
Directory names are case sensitive.
Examples
This example shows how to display the files in flash memory:
switch: dir flash:
Directory of flash:/
    3  -rwx        1839   Mar 01 2002 00:48:15  config.text
   11  -rwx        1140   Mar 01 2002 04:18:48  vlan.dat
   21  -rwx          26   Mar 01 2002 00:01:39  env_vars
    9  drwx         768   Mar 01 2002 23:11:42  html
   16  -rwx        1037   Mar 01 2002 00:01:11  config.text
   14  -rwx        1099   Mar 01 2002 01:14:05  homepage.htm 
   22  -rwx          96   Mar 01 2002 00:01:39  system_env_vars
17  drwx 
192    Mar 06 2002 23:22:03  cgesm-i612-mz.122-25.SE
 
15998976 bytes total (6397440 bytes free) 
 describes the fields in the display.
filesystem:
Alias for a flash file system. Use flash: for the system board flash device.
/file-url
(Optional) Path (directory) and directory name whose contents you want to 
display. Separate each directory name with a space.
Release
Modification
12.2(25)SE1
This command was introduced.
Table A-1
dir Field Descriptions
Field
Description
2
Index number of the file.
-rwx
File permission, which can be any or all of the following:
d—directory
r—readable
w—writable
x—executable