Cisco Cisco Mobility Unified Reporting Administrator's Guide
System Interface and Port Configuration Procedures
▀ Creating and Configuring Frame Relay Interfaces and Ports
▄ Cisco ASR 5000 System Administration Guide
104
OL-24498-04
Creating and Configuring Frame Relay Interfaces and Ports
This section shows the minimum configuration required to configure a frame relay interface on a channelized line card.
To create and configure the frame relay interfaces and ports:
To create and configure the frame relay interfaces and ports:
Step 1
Select a channelized line card (CLC/CLC2) and set the framing method by applying the example configuration in the
Step 2
Configure the path, framing, mapping, Frame Relay characteristics, and the data link connection identifiers (DLCIs) as
illustrated in the example configuration in the
illustrated in the example configuration in the
Step 3
Configure the appropriate timing source (BITS from the SPIO or line-timing from attached remote) to ensure transmit
synchronization by applying the example configuration in the Configuring Transmit Timing Source section in
Configuring System Settings.
synchronization by applying the example configuration in the Configuring Transmit Timing Source section in
Configuring System Settings.
Important:
Before you can move to Step 4 to bind a DLCI to a port, you must complete the link configuration
by configuring Peer-NSEIs and/or SS7 routing domains as described in SGSN Service Configuration Procedures in the
SGSN Administration Guide. Return to this procedure when your link configuration is complete.
SGSN Administration Guide. Return to this procedure when your link configuration is complete.
Step 4
Step 5
Verify the card, port and link configuration and status with the commands illustrated in the verification examples below.
Step 6
Save the configuration as described in Verifying and Saving Your Configuration.
Setting the Characteristics of the Channelized Line Card
Use the following example to set the operational characteristics, the framing type, the header type, the service type, and
the boot time E1 framing type, for the Frame Relay Channelized Line Card (CLC):
the boot time E1 framing type, for the Frame Relay Channelized Line Card (CLC):
configure
card <slot>
framing <framing_type> [ ds1 | e1 ]
header-type { 2-byte | 4-byte }
initial-e1-framing { crc4 | standard }
service-type frame-relay
no shutdown
end
Notes:
Make a note of the information you configure - you will need it again later for the path command used to
configure channel characteristics.