5222 
   
buckets
 
number
 
Default: 4 
Specifies the number of statistics container changes due to QoS changes or tariff time that can occur before 
an accounting record should be closed. 
number
 can be configured to an integer from 1 through 4. 
interval
 
time
 
[downlink
 
down_octets
 
uplink
 
up_octets
 
| total
 
total_octets
 
]
 
Specifies the normal time duration that must elapse before closing an accounting record provided that any or 
all of the following conditions occur: 
 
Downlink traffic volume is reached within the time interval 
 
Uplink traffic volume is reached within the time interval 
 
Total traffic volume (up and downlink) is reached within the time interval 
time
 is measured in seconds and can be configured to an integer from 60 through 40000000. 
down_octets
 is the downlink traffic volume measured in octets and can be configured to an integer from 0 
through 1000000. 
up_octets
 is the uplink traffic volume measured in octets and can be configured to an integer from 0 
through 1000000. 
total_octets
 is the total traffic volume measured in octets and can be configured to an integer from 0 
through 1000000. 
prepaid { prohibited | use-rulebase-configuration }
 
This command enables or disables prepaid for the specified profile index. 
Default: N/A 
prohibited
: Disable prepaid for the specified profile index. 
use-rulebase-configuration
: Use the prepaid configuration in the rulebase. 
sgsns
 
num_changes
 
Default: 4 
Specifies the number of SGSN changes (such as, inter-SGSN switchovers) resulting in a new RAI (Routing 
Area Identity) that can occur before closing an accounting record. 
num_changes
 can be configured to an integer from 1 through 15. 
tariff time1
 
mins hours
 
time2
 
mins hours
 
time3
 
mins hours
 
time4
 
mins hours
 
time5
 
mins hours
 
time6
 
mins hours
 
Specifies time-of-day time values to close the current statistics container (but not necessarily the accounting 
record). Six different tariff times may be specified. If less than six times are required, the same time can be 
specified multiple times. 
Important:
  The system assumes that the billing system uses the day/date to determine if the statistics container 
represents an actual tariff period. 
For each of the different tariff times, the following parameters must be configured: 
 
mins
: The minutes of the hour, an integer value from 0 to 59. 
 
hours
: The hour of the day, an integer value from 0 to 23.