• Raised When—Open means that the normal condition is no current flowing through the contact, and the alarm is generated
when current does flow; closed means that normal condition is to have current flowing through the contact, and the alarm is
generated when current stops flowing.
• Description—CTC alarm log description (up to 63 characters).
If you provision an external alarm to raise when a contact is open, and you have not attached the alarm
cable, the alarm will remain raised until the alarm cable is connected.
Note
When you provision an external alarm, the alarm object is ENV-IN-nn. The variable nn refers to the
external alarm’s number, regardless of the name you assign.
Note
External Controls
You can provision each alarm output separately. Provisionable characteristics of alarm outputs include:
• Control type.
• Trigger type (alarm or virtual wire).
• Description for CTC display.
• Closure setting (manually or by trigger). If you provision the output closure to be triggered, the following characteristics can
be used as triggers:
◦Local NE alarm severity—A chosen alarm severity (for example, major) and any higher-severity alarm (in this case,
critical) causes output closure.
◦Remote NE alarm severity—Similar to local NE alarm severity trigger setting, but applies to remote alarms.
◦Virtual wire entities—You can provision an alarm that is input to a virtual wire to trigger an external control output.