Step 3
To suppress alarms for individual cards, go to the shelf view and click the Provisioning > Alarm Profiles > Alarm
Behavior 
tabs:
a) In the alarm behavior window, locate the card row (using the Location column for the slot number or the Eqpt Type
column for the equipment name).
b) Check the Suppress Alarms column check box in that row.
Alarms that directly apply to this card will change appearance as described in
Step 2, on page 50
. For example, if you
suppressed raised alarms for an TXP_MR_10G card in Shelf 2, Slot 16, raised alarms for this card will change in node
or card view. The AS-CMD alarm will show the slot number in the Object number. For example, if you suppressed
alarms for a Slot 16 TXP_MR_10G card, the AS-CMD object will be “SLOT-2-16.”
c) Click Apply.
Step 4
To suppress alarms for ECU or ECU2 multishelf ports, go to the shelf view and click the Provisioning > Alarm Profiles
> ECU or ECU2 Multishelf Ports Alarm Suppression 
tabs:
a) In the ECU or ECU2 multishelf ports alarm suppression window, check the Suppress Alarms column check box for
the port where you want to suppress alarms.
b) Click Apply.
Alarms that apply directly to this port will change appearance as described in
Step 2, on page 50
.
Step 5
To suppress alarms for individual card ports, double-click the card in node view.
a) Click the Provisioning > Alarm Profiles > Alarm Behavior tabs.
b) Check the Suppress Alarms column check box for the port row where you want to suppress alarms.
c) Click Apply.
Alarms that apply directly to this port will change appearance as described in
Step 2, on page 50
. (However, alarms raised
on the entire card will remain raised.) A raised AS-CMD alarm that shows the port as its object will appear in either alarm
window. For example, if you suppressed alarms for Port 1 on the Slot 16 OC-48 card, the alarm object will show “FAC-16-1.”
Step 6
Return to your originating procedure (NTP).
DLP-G130 Discontinue Alarm Suppression
This task discontinues alarm suppression and reenables alarm reporting on a port,
card, shelf, or node.
Purpose
None
Tools/Equipment
• "DLP-G46 Log into CTC" task in the "
document.
Prerequisite Procedures
As needed
Required/As Needed
Onsite or remote
Onsite/Remote
Provisioning or higher
Security Level
51