If multiple CTC sessions are open, discontinuing suppression in one session will discontinue suppression
in all other open sessions.
Caution
Procedure
Step 1
To discontinue alarm suppression for the entire node:
a) In node view, click the Provisioning > Alarm Profiles > Alarm Behavior tab.
b) Clear the Suppress Alarms check box.
Suppressed alarms will reappear in the Alarms window. (They might have previously been cleared from the window using
the Synchronize button.) The AS-CMD alarm with the System object will be cleared in all views.
Step 2
To discontinue alarm suppression for individual cards:
a) In node view, click the Provisioning > Alarm Profiles > Alarm Behavior tabs.
b) Locate the card that is suppressed in the slot list.
c) Clear the Suppress Alarms column check box for that slot.
d) Click Apply.
Suppressed alarms will reappear in the Alarms window. (They might have previously been cleared from the window using
the Synchronize button.) The AS-CMD alarm with the slot object (for example, SLOT-16) will be cleared in all views.
Step 3
To discontinue alarm suppression for ECU or ECU2 ports, from the shelf view click the Provisioning > Alarm Profiles
> ECU or ECU2 Multishelf Ports Alarm Suppression 
tabs:
a) Clear the Suppress Alarms check box for the port(s) that you no longer want to suppress.
b) Click Apply.
Step 4
To discontinue alarm suppression for card ports, from the card view click the Provisioning > Alarm Profiles > Alarm
Behavior 
tabs.
a) Clear the Suppress Alarms check box for the port(s) that you no longer want to suppress.
b) Click Apply.
Suppressed alarms will reappear in the Alarms window. (They might have previously been cleared from the window using
the Synchronize button.) The AS-CMD alarm with the port object (for example, FAC-16-1) will be cleared in all views.
Step 5
Return to your originating procedure (NTP).
NTP-G72 Provision External Alarms and Controls on the Alarm Interface Controller-International
Card
Use this procedure to create external (environmental) alarms and external controls
for the AIC-I card.
Purpose
An AIC-I card must be installed in Slot 9.
Tools/Equipment