Cisco Cisco ONS 15454 M2 Multiservice Transport Platform (MSTP)

Page of 40
Removing and replacing cards can be traffic affecting.
Caution
Do not use this procedure to replace control cards.
Caution
Procedure
Step 1
Complete the "DLP-G46 Log into CTC" task in the "
document.
If you cannot log into Cisco Transport Controller (CTC) and you need to remove a card, remove the card as
described in
Step 6, on page 4
. After you log into CTC, troubleshoot the mismatched equipment alarm (MEA)
with the Cisco ONS 15454 DWDM Troubleshooting Guide .
Note
Step 2
Click the Alarms tab.
a) Verify that the alarm filter is not on. See the “DLP-G128 Disable Alarm Filtering” task in the
document as necessary.
b) Verify that no unexplained alarms appear on the network. If alarms appear, investigate and resolve them before
continuing. Refer to the Cisco ONS 15454 DWDM Troubleshooting Guide for procedures.
Step 3
If you are removing and replacing a card, go to
Step 5, on page 4
.
Step 4
If you are permanently removing a card, go to
Step 11, on page 5
.
Step 5
To remove and replace a card, complete the following tasks, as needed:
• The circuits traversing through the card that needs to be replaced (for example, an amplifier) need to be protection
switched. For instance, if the card you want to replace is an active transponder (TXP) or muxponder (MXP) in a
Y-cable protection group, complete the “DLP-G179 Apply a Force Y-Cable or Splitter Protection Switch” task in
the
document to force traffic away from the TXP or MXP that you will remove. If the card you
want to replace is the standby TXP or MXP in a Y-cable protection group, complete the “DLP-G182 Apply a Lockout”
task in the
document to prevent traffic from switching to the TXP or MXP that you will remove.
See the Cisco ONS 15454 Procedure Guide or the Cisco ONS 15454 SDH Procedure Guide for other types of
protection switching (path protection, BLSR, optical, and electrical).
• If the card is a node timing reference, complete the “NTP-G112 Change the Node Timing Reference” task in the
chapter “Maintain the Node” of the Cisco ONS 15454 DWDM Network Configuration Guide to change the timing
reference to a card that will not be removed.
• If the card is an OSCM or OSC-CSM with an optical service channel (OSC) or TXP, MXP, GE_XP, 10GE_XP,
GE_XPE, 10GE_XPE, ADM-10G, and OTU2_XP cards with generic communications channel (GCC) termination,
complete the “NTP-G85 Modify or Delete OSC Terminations, GCC Terminations, and Provisionable Patchcords”
procedure in the
document to delete the termination and recreate it on a card that will not be
removed.
Step 6
Physically remove the card:
a) Disconnect any cables.
b) Open the card latches/ejectors.
c) Use the latches/ejectors to pull the card forward and away from the shelf.
Step 7
Insert the new card using one of the following procedures as applicable:
4