Cisco Headend System Release 2.5
2-10
DNCS Configuration for Distributed BFS
738185 Rev B
Add an Additional BFS QAM to the DNCS,
Continued
15. Click Apply.
Results:
•
•
The system saves the QAM information you have entered up to this point
in the DNCS database.
•
The Hubs button in the Port To Hubs column becomes active.
16. Click Hubs. The RF Output Port window opens.
Notes:
•
•
The Basic Parameters area of this window shows the data that you entered
for key RF output fields.
•
The Associate Hubs area shows the hubs that are available to receive
content data from this QAM modulator.
17. Make sure the Selected Hubs field shows no hub names so that this QAM
modulator sends BFS and SI data to all hubs in the headend.
Note: To remove a hub name from the Selected Hubs field, select the hub
Note: To remove a hub name from the Selected Hubs field, select the hub
name, and then click Remove. The hub name moves to the Available Hubs
field.
18. Click Save to save this information into the DNCS database and close the RF
Output Port window.
19. Your next step is to set up the advanced parameters for the BFS QAM. Go to
Setting Up Advanced Parameters for the BFS QAM, next in this section.
Continued on next page