Cisco GainMaker Optoelectronic Node 1GHz with 65 86 MHz Split Installation Guide

Page of 180
Chapter 2    Installation and Configuration 
 
 
 
added to prevent shorting. 
4  Secure the cover to the amplifier module and tighten the amplifier cover screws. 
Tighten slotted head screws to 6 in-lb to 9 in-lb (0.7 Nm to 1.0 Nm), or cross head 
screws from 18 in-lb to 20 in-lb (2.0 Nm to 2.25 Nm). 
Important: The cover should lie completely flat on the amplifier module chassis. 
Make sure none of the amplifier module accessories prevent the cover from lying 
flat. 
5  Install other options or accessorie。red, or proceed to 
Installing the Amplifier 
Module (on page 37). 
 
To Install the Plug-in Signal Director 
Complete the following steps to install the signal director in the amplifier module. 
1  Open the node housing. Refer to 
To Open the Node Housing (on page 17). 
Note:  This accessory can be installed without removing the amplifier module 
cover. 
2  Be sure to install the correct signal director for your system as specified by the 
design print. 
If you are installing a ... 
This will ... 
Jumper, part number 4008208 
activate only one auxiliary port. 
Splitter, part number 4008364 
activate both auxiliary ports with equal 
signal levels. 
8 dB Coupler, part number 4008365 or 
12 dB Coupler, part number 4008366 
activate both auxiliary ports with differing 
signal levels. 
3  Install the signal director in the signal director slot. Refer to the following 
diagram for the location of the signal director slot. 
 
34 
OL-30326-02