Cisco GainMaker Optoelectronic Node 1GHz with 65 86 MHz Split Installation Guide

Page of 174
 
 
Removing and Installing AC Shunt Power Directors 
 
Removing and Installing AC Shunt Power 
Directors 
The amplifiers draw AC power from the coaxial cable. This AC power comes from 
an external AC power supply. 
    WARNING: 
When AC is applied from RF ports to units downstream, the 
downstream equipment shall also be located in a restricted access 
location (access restricted to service personnel). 
Power can come from the input or output ports, and each amplifier can pass or block 
AC power flow on any port without affecting RF continuity. However, at least one 
port must pass AC power to bring power into the amplifier. 
To set the power direction, install AC shunt power directors for the ports through 
which you wish to pass AC. 
Note: A red AC shunt power director is included with the unit. The red shunt is 
used to activate the port that supplies power. The red shunt should be removed 
before installing or removing the amplifier module from the housing. 
 
CAUTION: 
RF connectors and housing seizure assemblies can be damaged if AC 
shunt power directors are not removed from the amplifier before 
installing or removing the amplifier module from the housing. 
 
To Remove and Insert AC Shunt Power Directors 
Complete the following steps to remove and insert AC shunt power directors. 
1  Open the node housing. Refer to 
To Open the Node Housing (on page 15). 
2  To remove a power director, pull it straight out from the amplifier module. 
 
3  To insert a power director, refer to the systems design print to determine AC 
power routing and install the AC shunt power directors in the required 
locations. 
 
OL-29644-03 
35