Cisco GainMaker Optoelectronic Node 1GHz with 65 86 MHz Split Installation Guide

Page of 182
 
Forward Path Balancing for AGC Stations Using Manual Setup Mode 
3  Turn the MANUAL BACKOFF potentiometer fully counterclockwise for 
maximum gain. 
 
4  Determine the outside temperature at the amplifier location. 
5  Refer to the 
Manual Backoff Chart (on page 55) to find the proper manual 
backoff level for the current temperature and reference frequency. 
6  Turn the MANUAL BACKOFF potentiometer clockwise to reduce the output 
level by the amount specified in the Manual Backoff Chart. 
Note: After making this adjustment, do not adjust the MANUAL BACKOFF 
potentiometer again. 
7  Proceed to To Determine the Output Tilt
 
Manual Backoff Chart 
The following table displays the manual backoff level for selected frequencies and 
various temperatures. 
 
Temperature 
445.25 MHz 
Backoff level 
547.25 MHz 
Backoff level 
870 MHz 
Backoff level 
1 GHz 
Backoff level 
60°C 
140°F 
0.0 dB 
0.0 dB 
0.0 dB 
0.0 dB 
55°C 
131°F 
0.4 dB 
0.4 dB 
0.6 dB 
0.6 dB 
50°C 
122°F 
.7 dB 
.8 dB 
1.1 dB 
1.2 dB 
45°C 
113°F 
1.1 dB 
1.3 dB 
1.7 dB 
1.8 dB 
40°C 
104°F 
1.5 dB 
1.6 dB 
2.2 dB 
2.4 dB 
35°C 
95°F 
1.9 dB 
2.1 dB 
2.8 dB 
3.0 dB 
30°C 
86°F 
2.3 dB 
2.5 dB 
3.4 dB 
3.6 dB 
25°C 
77°F 
2.6 dB 
2.9 dB 
3.9 dB 
4.2 dB 
20°C 
68°F 
3.1 dB 
3.4 dB 
4.5 dB 
4.8 dB 
15°C 
59°F 
3.4 dB 
3.7 dB 
5.0 dB 
5.4 dB 
10°C 
50°F 
3.7 dB 
4.1 dB 
5.5 dB 
5.9 dB 
5°C 
41°F 
4.1 dB 
4.5 dB 
6.0 dB 
6.4 dB 
0°C 
32°F 
4.4 dB 
4.9 dB 
6.5 dB 
7.0 dB 
 
OL-30035-03 