Cisco Headend System Release 2.5 Installation Guide

Page of 280
78-738190-01 Rev B 
SR 2.5 and SR 3.5 UniPack Pre-Upgrade Procedures 
1-25 
Connect the UniPack to the DNCS 
Connecting the UniPack 
Follow this procedure to connect the UniPack to the DNCS. 
Note:  Unlike previous system upgrades that used a UniPack, you do not have to 
stop the system components before connecting the UniPack to the DNCS. 
 
1. 
 
Follow these instructions to connect the UniPack to the DNCS. 
Note:  Refer to the illustration that accompanies these instructions as you 
connect the UniPack. 
a)  Be sure the power switch of the UniPack is in the off position (noted as O 
on the side of the switch). 
b)  Verify that the SCSI switch, labeled SCSI Switch in the illustration, is set 
to 3
Note:  The UniPack ships with this switch set to 3, but it may have 
changed in transit or set up. 
c)  Connect one end of an FW SCSI cable to the SCSI port labeled IN, and the 
other end to the DNCS. 
Important:  On the V880 DNCS, use the upper port of slot 6; select any 
port on the motherboard for the Enterprise 450 or Enterprise 250. 
d)  Plug one end of the power cable into the back of the UniPack, and the 
other end into an AC power outlet.