DHCT Errors 
736107 Rev D 
113 
 
If you stage a DHCT and the EMM count is correct, but the ISE errors continually 
increment, ask the DNCS operator to verify that the DNCS MAC address and the 
Secure Micro Address match the CableCARD module. Then, ask the DNCS operator 
to run the modDhctCfg -s [MAC address of the CableCARD module] command. If 
this does not work, contact Cisco Services to obtain new EMMs for the SSC DHCT 
and try to stage the SSC DHCT again. 
 
DHCT Errors Solutions Table 
The following table lists some common symptoms, the corresponding LED display, 
and possible solutions to the problem. These symptoms and solutions are for DHCTs 
with full display, alphanumeric LEDs. For DHCTs with single- or triple-LEDs, see 
SSC DHCT Errors Solutions Table for Single- and Triple-LED DHCTs (on page 117). 
Note: If you must return a SSC DHCT to us for repair. 
Symptom 
Possible Solution 
DHCT displays the 
following symptoms: 
 
No display 
 
POWER button does not 
work 
Switch the AC input and power cycle the DHCT. 
If these steps do not work, return the SSC DHCT to 
us for repair. Mark the repair tag with F1. No 
Power/Bad Keypad Button
DHCT displays the 
following symptoms: 
 
No display 
 
POWER button works 
Follow these steps: 
Connect the DHCT to a known good RF cable.  
Power cycle the SSC DHCT.  
Wait 5 minutes. 
If these steps do not work, return the SSC DHCT to 
us for repair. Mark the repair tag with D2. Unable 
to Connect to Network.