Cisco Headend System Release 2.7

Page of 174
 
 
PowerKEY/EA Issues 
736107 Rev D 
127 
 
PowerKEY/EA Issues 
This section provides a list of suggested solutions for problems that result from 
PowerKEY Conditional Access or EA. 
 
 
 
Symptom 
Type of 
DHCT 
Possible Solution 
No 
Entitlement 
Agent (EMMs) 
Unstaged 
Does the CableCARD module's MAC address match the 
MAC address recorded in the billing system? 
– 
If yes, follow these steps: 
i  Confirm that the actual MAC address for the 
module matches the MAC address recorded in the 
DNCS. 
ii  Confirm that the Secure Micro Address for the 
module matches the Secure Micro Address recorded 
in the DNCS. 
iii  Ask the DNCS operator to perform a  
modDhctCfg -s [MAC address of the module] on 
the CableCARD module. 
iv  Stage the CableCARD module again. 
– 
If no, follow these steps: 
i  Ask the DNCS operator to correct any existing 
mis-matches. 
ii  Stage the CableCARD module again. 
iii  Go to step 2 if these actions do not remedy the 
situation. 
Follow these steps: 
Take the SSC DHCT out of service. 
Try to stage the SSC DHCT again. 
Follow these steps: 
Delete the SSC DHCT from the DNCS. 
Contact us to have new EMMs built. 
Try to stage the SSC DHCT again using the new EMMs. 
If these steps do not work, return the SSC DHCT to us for 
repair. Mark the repair tag with S1. No EMMs/ISE/EA.