PowerKEY/EA Issues 
736107 Rev D 
129 
 
Symptom 
Type of 
DHCT 
Possible Solution 
No Incoming 
EMMs 
Unstaged 
Does the DNCS have the EMMs loaded for the CableCARD 
module? 
If yes, follow these steps: 
i  Ask the DNCS operator to perform a  
modDhctCfg -s [MAC address of the module] on 
the CableCARD module. 
ii  Stage the CableCARD module again. 
If no, contact us to get the correct EMMs. 
Does the CableCARD module's MAC address match the 
MAC address recorded in the billing system? 
– 
If yes, follow these steps: 
i  Confirm that the actual MAC address for the 
module matches the MAC address recorded in the 
DNCS. 
ii  Confirm that the Secure Micro Address for the 
module matches the Secure Micro Address recorded 
in the DNCS. 
iii  Ask the DNCS operator to perform a  
modDhctCfg -s [MAC address of the module] on 
the CableCARD module. 
iv  Stage the CableCARD module again. 
– 
If no, follow these steps: 
i  Ask the DNCS operator to correct any existing mis-
matches. 
ii  Stage the CableCARD module again. 
iii  Go to step 3 if these actions do not remedy the 
situation. 
If these steps do not work, return the SSC DHCT to us for 
repair. Mark the repair tag with S1. No EMMs/ISE/EA. 
 
No Incoming 
EMMs 
Deployed 
Follow these steps: 
Confirm that the DHCT boots into two-way mode (that 
it has an IP address listed on the diagnostic screens, if 
applicable). 
Ask the DNCS operator to send an instant hit to the 
CableCARD module. 
Stage the CableCARD module again. 
If these steps do not work, return the SSC DHCT to us for 
repair. Mark the repair tag with S1. No EMMs/ISE/EA.