Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Installation Guide

Page of 282
 
Chapter 2    Theory of Operation 
 
 
 
56 
OL-29643-02 
[B] In Constant Power mode only. 
Operating Status Parameters 
The following table defines the monitored operating parameters for the EDFA. 
 
Parameter Name 
Function 
Typical Value  Units 
Optical Input Power 
Optical input power 
5.0 
dBm 
Output Power 
Optical output power 
19.5 
dBm 
Laser Temperature 
Laser temperature 
25.0 
degC 
Laser Bias Current 
Limit 
Laser operating current 
limit 
0.825 A 
Laser Bias Current 
Laser operating current 
0.625 
TEC Current 
Thermoelectric cooler 
current 
0.25 A 
Module Temperature  Module temperature 
26.5 
degC 
Laser On Time 
Time the laser has been on 
1.0 
Hrs 
 
Alarm Parameters 
The following table defines the alarm parameters for the EDFA. 
 
Alarm Name  Major 
High 
Minor 
High 
Minor 
Low 
Major 
Low 
Values
Typical 
Value 
Hysteresis Units 
Laser Bias 
Current 
-0.001 
-0.010 
na na Ok 
Alarm
0.625 0.001 
Optical 
Output 
Level 
1.0 0.7 -0.7 -1.0 Ok 
Alarm
17 
20 
21 
22 
0.1 dBm 
Input Power 
[1] 
[5] [5] [5] [5] Ok 
Alarm
na 0.1 
dBm 
Laser 
Temperatur
e [1][4] 
20.0 15.0 -15.0 -20.0 Ok 
Alarm
25.0 1.0 
degC
OIB Voltage 
Status [1][2] 
na na na na Ok 
Alarm
Ok na 
na 
Internal 
Power 
Status [1][3] 
na na na na Ok 
Alarm
na na 
na