Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Installation Guide

Page of 282
 
Chapter 2    Theory of Operation 
 
 
 
58 
OL-29643-02 
 
Broadcast EDFA - Constant Gain Mode 
 
Product Type 
Major 
High 
Minor 
High 
Minor 
Low 
Major 
Low 
Values Typical 
Value 
Hysteresis Units 
17.0/20.0/22.0 
dBm 
45.0  25.0  -13.0 -15.0 Ok 
Alarm 
-12.0 0.1 
dBm 
 
Laser Temperature Set Point Adjustment 
In an effort to reduce EDFA power consumption, laser temperature set point is 
changed based on EDFA module temperature. Typically, the laser temperature set 
point is set at 25°C. When module temperature is greater than 60°C and less than 
10°C, laser temperature set point is adjusted. 
Hot Condition (Module Temperature > 60°C) 
For module temperature less than 60.0°C, laser set point temperature is set at 25°C. 
For every degree of module temperature greater than 60°C, laser set point 
temperature is also increased by that amount until module temperature reaches 70°C, 
then laser temperature set point is fixed at 35°C.    For example, if module 
temperature is 64°C, laser set point temperature is 29°C. If module temperature is 
85°C, laser set point temperature is 35°C. 
Cold Condition (Module Temperature < 10°C) 
For module temperature greater than 10°C, laser set point temperature is set at 25°C. 
For every degree of module temperature less than 10°C, laser set point temperature 
is also decreased by that amount until the module temperature reaches -5°C, then 
laser temperature set point is fixed at 10°C. For example, if module temperature is 
-4°C, laser set point temperature is 11°C. If module temperature is -25°C, laser set 
point temperature is 10°C.