Cisco Model GS7000 4-Port Node 1 GHz with 42 54 Split Installation Guide

Page of 282
 
 
Optical Amplifier (EDFA) Modules 
OL-29643-02 
57 
 
Alarm Name  Major 
High 
Minor 
High 
Minor 
Low 
Major 
Low 
Values
Typical 
Value 
Hysteresis Units 
Laser 
Enabled 
Status [1] 
na na na na Ok 
Alarm
na na 
na 
[1] This alarm sets the unit to the safe state. In the safe state, the amplifier is turned 
off causing the optical amplifier output to be disabled. 
[2] This alarm tests for presence of +24V, -6V from the OIB. 
[3] This alarm indicates the state of the internal voltages (+24V, +5.0V, Vref). 
[4] See following for laser nominal set point temperature based on module 
temperature. 
[5] See next table for input power alarm values. 
Input Power Alarm Parameters 
The following tables define the input power alarm parameters for the EDFA. 
Narrowcast (gain-flattened) EDFA - Constant Gain Mode (Default) 
 
Product Type 
Major 
High 
Minor 
High 
Minor 
Low 
Major 
Low 
Values Typical 
Value 
Hysteresis Units 
17.0 / 20.0 
/21.0 dBm 
Low Gain 
45.0 25.0 -8.0  -10.0 Ok 
Alarm 
-7.0 0.1 
dBm 
17.0 / 20.0 
/21.0 dBm 
High Gain 
45.0  25.0  -13.0 -15.0 Ok 
Alarm 
-12.0 0.1 
dBm 
 
Narrowcast (gain-flattened) EDFA - Constant Power Mode 
 
Product Type 
Major 
High 
Minor 
High 
Minor 
Low 
Major 
Low 
Values Typical 
Value 
Hysteresis Units 
17.0 / 20.0 
/21.0 dBm 
Low/High 
Gain 
45.0 25.0 0 
-10.0 Ok 
Alarm 
5.0 0.1 
dBm 
 
Broadcast EDFA - Constant Power Mode (Default) 
 
Product Type 
Major 
High 
Minor 
High 
Minor 
Low 
Major 
Low 
Values Typical 
Value 
Hysteresis Units 
17.0/20.0/22.0 
dBm 
45.0 25.0 0 
-10.0 Ok 
Alarm 
5.0 0.1 
dBm