Chapter 6    Troubleshooting the Netcrypt Bulk Encryptor 
 
 
 
98 
4001444 Rev C 
Alarm Conditions 
This section describes major, minor, and status alarms. See Troubleshooting With 
Alarm Manager (on page 100) for a list of alarms and possible solutions. 
Purpose and Severity Levels of Alarm Indicators 
Alarms provide system operators with an indication of an abnormal condition. 
Alarm indicators turn on when hardware or software conditions occur that might 
cause the Netcrypt Bulk Encryptor to operate incorrectly or fail. Examples of such 
conditions include temperature fluctuations, power supply failure, communication 
problems, or the detection of bad data. All alarms are automatically enabled after 
powering up the Netcrypt Bulk Encryptor.  
The following table describes each of the status and alarm indicators on the front 
panel of the Netcrypt Bulk Encryptor. 
Status Indicators 
Indicator 
Description 
POWER 
When the POWER indicator lights, the Netcrypt Bulk Encryptor is 
receiving power. 
RUN/LOAD 
When the RUN/LOAD indicator lights, the Netcrypt Bulk 
Encryptor is running under normal conditions. When the 
RUN/LOAD indicator blinks, the Netcrypt Bulk Encryptor is 
downloading a new version of code. 
Alarm Indicators 
Title 
Title 
MINOR 
ALARM 
When the MINOR ALARM indicator lights, a non-fatal error 
condition is pending. Under this condition, the Netcrypt Bulk 
Encryptor may continue to operate with some loss of functionality. 
MAJOR 
ALARM 
When the MAJOR ALARM indicator lights, a fatal error condition is 
pending. A fatal error indicates a complete loss of functionality. 
Major alarms occur for hardware or software conditions that 
indicate a serious disruption of service or the malfunctioning or 
failure of important circuits. These situations require the immediate 
response of the technician to restore or maintain system operability.