Cisco Model D-PCG1000 PowerKEY CAS Gateway Installation Guide
Alarm Conditions
4001444 Rev C
99
Front Panel Alarm Indicators
The following table lists the conditions that cause MAJOR ALARM and MINOR
ALARM indicators to turn on.
Note: For additional information on each of the alarm descriptions listed here, see
Note: For additional information on each of the alarm descriptions listed here, see
Troubleshooting With Alarm Manager (on page 100).
Alarm Level
Alarm Description
MINOR ALARM
Temperature Exceeded
Input (1-8) MPEG continuity error
Input (1-8) MPEG Transport error
Input (1-8) errored MPEG packets
Input (1-8) FIFO overflow
Output (1-8) FIFO overflow
Output (1-8) packets were dumped
Input (1-8) ECM PID conflict
Power supply failure
MAJOR ALARM
Input (1-8) loss of input signal
Ethernet loss of signal
Hardware error
Runtime error (operating system)
Input (1-8) auto negotiate failure
Fan (1 - 5) failure
Session xxx data error, where xxx is a number from 0 to
991