Cisco Headend System Release 2.7 User Guide

Page of 282
 
Chapter 2    Analyze System Configuration with the Doctor Report 
 
 
 
30 
4031374 Rev B 
to where set-tops obtain SDV service group mapping and configuration data. 
 
StatMUX Dejitter Groups 
The StatMUX Dejitter Groups field provides a list of statMux dejitter groups, as well 
as the GQAM and output ports to which they are assigned. 
 
Generic QAMs 
The Generic QAM field provides a list of third-party QAMs, and includes the type of 
QAM, the name of the QAM, as well as the IP address of the QAM. 
 
Dual GbE GQAMs 
The Dual GbE GQAMs field lists the GQAMs that have dual GbE input, as well as 
the port configurations for each GbE port. 
 
DNCS/App Server Time Sync 
The data in the DNCS/App Server Time Sync field reports on the following system 
time details: 
 
Time differences between the DNCS and the Application Server 
 
Network time protocol used on the DNCS and the Application Server (xntpd or 
ntpd) 
 
Time synchronization source (local or GPS) 
Rovi Note:   Ignore errors at sites that run the Rovi resident application. 
Important:  If the system reports an error in the time synchronization between the 
DNCS and the Application Server, change the time on the Application Server. 
 
Timezone and Daylight Savings Time Check 
The data in the Timezone and Daylight Savings Time Check field summarizes the 
time zone and daylight savings time (DST) settings for hubs and DHCTs. 
Note: The DHCT Summary section should show Follow hub in the columns 
Timezone Offset and DST Observed
Important: If the DHCT Summary section shows Yes or No in the DST Observed 
column, contact Cisco Services for assistance in configuring all DHCTs to follow the 
time of the hub to which they belong.