Calculate and Change the OOB CVT Message Cycle Time 
 
4024836 Rev D 
73 
 
8  In an xterm window, type . ./.profile to source the environment variable. Be sure 
to type a space between the first two periods. 
9  Type env | grep OSM and press Enter. The system displays the environmental 
variables associated with the OSM process. 
10  Is the OSM_RF_CVT_PASSTHRU_SECONDS included in the list and is the 
setting correct? 
 
If yes, you are finished with this procedure. Go to Bouncing the OSM Process 
(on page 73). 
 
If no, repeat this process from step 3. 
 
Bouncing the OSM Process 
After you have added the environment variable to the .profile file, you must bounce 
(stop and restart) the OSM process. 
1  If the DNCS Control window is not already open, click the Control button in the 
DNCS area of the DNCS Administrative Console Status window. 
 
Result: The DNCS Control window opens. 
2  From the list of processes, click osm
3  Click Process > Stop Process. A confirmation message appears. 
4  Click Yes to stop the OSM process. This causes the indicator next to OSM to turn 
red. 
5  From the list of processes, click osm
6  Click Process > Start Process. The indicator next to osm turns green when the 
osm process has successfully restarted. 
7  Go to 
Test the Updated OOB CVT Message Cycle Time (on page 74).