Cisco Cisco StadiumVision Mobile Streamer Maintenance Manual

Page of 103
 
 
© 2012 Cisco Systems, Inc. All rights reserved.   
 
Page 65 of 103 
Serial Command 
String 
Volume10  
rs232.tx_hex=6B662030312035300D  
Volume11  
rs232.tx_hex=6B662030312035350D  
Volume12  
rs232.tx_hex=6B662030312036300D  
Note: It is a best practice to set Volume1 at a value above zero. A zero volume level is 
considered as a mute and when the user adjusts the volume up, some displays show the 
status bar as if their volume is turned up, but the display remains muted.  
Relative Volume Commands 
To define relative volume controls for the attached TV: 
1.  On the Serial Commands tab for the desired TV type, click the + at the upper 
right of the Available Serial Commands list box. 
2.  Click + at the upper right of the Available Serial Commands box and add a 
corresponding command called VolumeUp. 
3.  Press Enter. 
4.  The VolumeUp will automatically be selected in the available list. Click << to add 
it to the configured list.  
5.  Select the VolumeUp command in the configured list and click + at the upper 
right of the Serial Strings of Selected Commands. Enter the appropriate RS-232 
command to increase the volume. 
6.  Press Enter. 
7.  Repeat steps 1 through 6 to define a command for VolumeDown. 
8.  Click Save
Repeating Relative Volume Serial Commands 
As previously mentioned, the VolumeUp and VolumeDown commands rely upon the 
incremental volume settings that are internal to each model of TV. For some TVs, 
the increase/decrease in volume is very slight, requiring multiple VolumeUp or 
VolumeDown commands to achieve the desired effect. For these TVs, you can add 
and define a serial command with the label “dmp.RelativeVolumeSteps.”  
The value that you specify for dmp.RelativeVolumeSteps represents the number of 
times the RS-232 command for VolumeUp or VolumeDown will be repeated when 
you press up or down on the IR remote (or on the phone). For example, if 
dmp.RelativeVolumeSteps is set to 8, then a VolumeUp command will result in 8 
copies of the up string being sent, rather than just one. If dmp.RelativeVolumeSteps 
is not set, then the default value is 1.