38. For each volume increment in the VolumeCount (1 through n):
a. Click + at the upper right of the Available Serial Commands box and add a
corresponding command called Volumex, where x is a number (1 through n)
that identifies the input. Do not prefix a leading, i.e. the first level should be
Volume1 and not Volume01.
that identifies the input. Do not prefix a leading, i.e. the first level should be
Volume1 and not Volume01.
b. Select the Volumex command in the available list and click << to add it to the
configured list.
c. Select the Volumex command in the configured list and click + at the upper
right of the Serial Strings of Selected Commands. Enter the appropriate RS-
232 command for that level of volume. For example, you might configure
"Volume1" with the RS-232 command that sets the TV Volume to the 5%
volume level.
232 command for that level of volume. For example, you might configure
"Volume1" with the RS-232 command that sets the TV Volume to the 5%
volume level.
39. Click Save. This string will now be associated with the configured serial
command for the selected device.
Below is an example of volume commands for an LG Display with a VolumeCount
of 12.
of 12.
Serial Command
String
Volume1
rs232.tx_hex=6B662030312030350D
Volume2
rs232.tx_hex=6B662030312031300D
Volume3
rs232.tx_hex=6B662030312031350D
Volume4
rs232.tx_hex=6B662030312032300D
Volume5
rs232.tx_hex=6B662030312032350D
Volume6
rs232.tx_hex=6B662030312033300D
Volume7
rs232.tx_hex=6B662030312033350D
Volume8
rs232.tx_hex=6B662030312034300D
Volume9
rs232.tx_hex=6B662030312034350D