Cisco Cisco Prisma II EDR Receiver Data Sheet

Page of 5
 
Page 3 of 5 
Specifications 
 
Optical 
Units 
HDTx 
Premium 
HDTx 
Standard 
Notes 
Nominal Optical Output Wavelength 
nm 
1310 
± 20 
 
Optical Interface 
    SC/APC 
    SC/UPC 
    E2000 
 
 
Standard 
Optional 
Optional 
 
Optical Output Power 
dBm 
dBm 
dBm 
dBm 
dBm 
dBm 
dBm 


10 
12 
14 
15 



10 
12 
 
Electrical 
Bandwidth 
MHz 
46 - 1002 
 
Frequency Response  
dB 
± 0.6 
 
Input Return Loss  
dB 
>16.0  
 
Port-to-Port Isolation 
  (New Media to Broadcast Inputs) 
dB > 
50   
Broadcast (BC) RF Input 
Required RF Input Level per Ch. (NTSC)  
78 NTSC analog ch’s with: 
-320 MHz QAM (550-870 MHz) @ -6 dB 
-450 MHz QAM (550-1002 MHz) @ -6 dB 
 
64 PAL B/G analog ch’s with: 
-270 MHz QAM (600-870 MHz) @ -6 dB 
-400 MHz QAM (600-1002 MHz) @ -6 dB 
 
59 PAL D/K analog ch’s with: 
-270 MHz QAM (600-870 MHz) @ -6 dB 
-400 MHz QAM (600-1002 MHz) @ -6 dB 
 
 
 
dBmV 
dBmV 
 
 
dBmV 
dBmV 
 
 
dBmV 
dBmV 
 
 
 
15.3 
15.0 
 
 
16.3 
16.0 
 
 
16.6 
16.3 
 
 
 
Narrowcast (NC) RF Input 
Required RF Input Level per Ch. (QAM) 
-for QAM @ -6 dBc relative to analog ch’s 
Required RF Input Level per Ch. (analog) 
- for equal amplitude analog ch’s (BC and NC) 
 
 
dB 
 
dB 
 
 
 
+6 
 
+12 
(above Broadcast RF analog level) 
 
 
Power Consumption (maximum) 
W DC 
7.5 
 
Front Panel Test Point 
  Relative to Input 
 
dB 
 
dB 
Broadcast Input 
-20 
± 0.5 @ 
Narrowcast Input 
-32 
± 0.5@ 
 
Environmental 
Operating Temperature Range 
 
 
 
  Full Specs 
 
  Storage 
 
°C 
°F 
°C 
°F 
-20 to +65* 
-4 to +149 
-40 to +65 
-40 to +149 
0 to +50 
+32 to +122 
-40 to +65 
-40 to +149 
Humidity Range 
0 to 95 
 
Mechanical (Modules) 
Depth in. 
8.80 
 
 cm 
22.35 
 
Width in. 
1.03 
 
 cm 
2.62 
 
Height in. 
3.48 
 
 cm 
8.84 
 
Weight lb 
0.90 
 
 kg 
0.41 
 
Module Width 
slots 
 
*(0~50
°C for -T version, 4 to 10 dBm)