Cisco Cisco Prisma II EDR Receiver Data Sheet

Page of 5
 
Page 4 of 5 
Link Performance Specifications 
 
Premium HDTx 
Carrier to Noise 
(see notes: 1,3,4,5) 
78 CW NTSC with 53 QAM
256
  (550-870 MHz) 
64 CW PAL B/G or 59 CW PAL D/K with 33 QAM
256
  (600-870 MHz) 
Total Optical Link Loss (dB)
 
Model # 
Output 
Power 
(dBm) 
3 4 5 6 7 8 9 10 
11 
12 
13 
14 
15 
16 
17 
HD-13TXF-04 4 
54.5  53.5  52.5  51.5 
           
HD-13TXF-06 6   
 
54.5  53.5  52.5  51.5 
         
HD-13TXF-08 8   
 
 
 
54.5  53.5  52.5  51.5 
       
HD-13TXF-10 10   
 
 
 
 
 
54.5  53.5  52.5  51.5 
     
HD-13TXF-12 12   
 
 
 
 
 
 
 
54 
53 
52 
51      
HD-13TXF-14 14   
 
 
 
 
 
 
 
 
 
53.5  52.5  51.5  50.5  
HD-13TXF-15 15   
 
 
 
 
 
 
 
 
 
 
53 
52 
51 
50 
 
Standard HDTx 
Carrier to Noise 
(see notes: 1,3,4,5) 
78 CW NTSC with 53 QAM
256
  (550-870 MHz) 
64 CW PAL B/G or 59 CW PAL D/K with 33 QAM
256
  (600-870 MHz) 
Total Optical Link Loss (dB)
 
Model # 
Output 
Power 
(dBm) 
2 3 4 5 6 7 8 9 10 
11 
12 
13 
14 
HD-13TXTS-03 3  52.5 
51.5 
50.5 
49.5 
 
 
 
 
 
 
 
 
 
HD-13TXTS-05 5 
   
52.5 
51.5 
50.5 
49.5 
 
 
 
 
 
 
 
HD-13TXTS-06 6 
     
52.5 
51.5 
50.5 
49.5 
 
 
 
 
 
 
HD-13TXTS-08 8 
     
 
 
52.5 
51.5 
50.5 
49.5 
 
 
 
 
HD-13TXTS-10 10 
 
 
 
 
 
 
 
52 
51 
50 
49    
HD-13TXTS-12 12 
 
 
 
 
 
 
 
 
 
52 
51 
50 
49 
 
 
Distortion Performance 
(all HD-Tx’s) 
78 CW NTSC  with up to 75 QAM
256
  (550-1002 MHz) 
64 CW PAL B/G or 59 CW PAL D/K with up to 50 QAM
256
  (600-1002 MHz) 
Notes 
CTB 70 
1, 
CSO 65 
1, 
4
 
XMOD 65 
1, 
 
 
256 QAM BER Performance 
(all HD-Tx’s) 
78 CW NTSC (55-550 MHz) with up to 75 QAM
256
 (-6 dB, 550-1002 MHz) 
Notes 
Pre-FEC BER (typical) 
≤ 1.0 e-6 
1, 4, 6, 7 
 
 
Notes: 
1. 
At specified RF input level.  RF levels shown are required with Tx AGC off. 
2. 
Narrowcast Input requires an RF input level that is greater than the RF input to Broadcast. 
3. 
Total optical link loss allows 3.5 dB for passive loss with balance of all fiber loss. 
4. 
All measurements taken with Scientific-Atlanta 6940/44/GainMaker Node Receiver. 
5. 
For 78 NTSC, 64 PAL B/G, or 59 PAL D/K with QAM
256
 loading through 1002 MHz, subtract 0.3 dB from listed CNR. 
6. 
Pre-FEC BER specified for ITU-T J.83 Annex B 256 QAM modulation, 78 NTSC in CW mode, 15 minute test duration w averaged BER. 
7. 
Pre-FEC BER improves to ≤ 1.0 e-9 when tested with 78 NTSC carriers modulated with independent NTSC video sources. 
8. 
Temperature at air inlet to Prisma II chassis. 
 
 
Unless otherwise noted, specifications are minimum performance over temperature.  Specifications are based upon measurements made in 
accordance with SCTE/ANSI standards (where applicable), using standard frequency assignments.