Cleaning Optical Connectors 
 
78-4025693-01 Rev D 
21 
 
To Clean Optical Connectors 
 
    WARNING: 
 
Avoid personal injury! Use of controls, adjustments, or performance of 
procedures other than those specified herein may result in hazardous 
radiation exposure. 
 
Avoid personal injury! The laser light source on this equipment emits 
invisible laser radiation. Avoid direct exposure to the laser light source. 
 
Avoid personal injury! Viewing the laser output with optical instruments 
(such as eye loupes, magnifiers, or microscopes) may pose an eye hazard. 
 
Connect or disconnect fiber only when equipment is OFF or in Service mode. 
 
Do not apply power to this equipment if the fiber is unmated or unterminated. 
 
Do not look into an unmated fiber or at any mirror-like surface that could reflect 
light that is emitted from an unterminated fiber. 
 
Do not view an activated fiber with optical instruments such as eye loupes, 
magnifiers, or microscopes. 
 
Use safety-approved optical fiber cable to maintain compliance with applicable 
laser safety requirements. 
Fiber Optic Connector Cleaning Instructions 
Connector cleanliness is crucially important for optimum results in fiber optic 
communications links.  Even the smallest amount of foreign material can make it 
impossible to obtain the expected insertion and return losses.  This can reduce the 
range of the equipment, shorten its expected service life, and possibly prevent the 
link from initializing at all. 
New equipment is supplied with clean optical connectors and bulkheads.  Clean 
these connectors and bulkheads in the field only if you observe and can verify an 
optical output problem. 
Connectors and Bulkheads 
Most fiber optic connectors are of the physical contact (PC) type.  PC type connectors 
are designed to touch their mating connector to prevent air gaps, which cause 
reflections.  For optimum performance, all dirt must be removed. 
Bulkheads can also become dirty enough to affect performance, either from airborne 
dust or from contamination introduced by connectors.