Chapter 2    Module Installation 
 
 
 
22 
78-4025693-01 Rev D 
 
    WARNING: 
Avoid damage to your eyes!  Do not look into any optical connector while the 
system is active.  Even if the unit is off, there may still be hazardous optical 
levels present. 
Note:  Read the above warning before performing cleaning procedures. 
Cleaning Connectors 
It is important that all external jumper connectors be cleaned before inserting them 
into the optical module.  Follow these steps to clean fiber optic connectors that will 
be connected to the optical module: 
Important:  Before you begin, remove optical power from the module or ensure that 
optical power has been removed. 
1  Inspect the connector through an optical connector scope.  If the connector is 
damaged, e.g., scratched, burned, etc., replace the jumper. 
2  If the connector is dirty but otherwise undamaged, clean the connector as 
follows: 
a  Make several swipes across the face of the connector with a CLETOP ferrule 
cleaner.  This will remove dust and some films. 
b  Listen for a slight "squeak" typically generated during this process, indicating 
a clean connector. 
c  Inspect the connector again through the scope to confirm that it is clean. 
3  If a second inspection indicates that further cleaning is needed: 
a  Use 99% isopropyl alcohol and a lint-free wipe to clean the connector. 
b  Use the CLETOP ferrule cleaner again to remove any film left over from the 
alcohol. 
c  Inspect the connector again through the scope and confirm that it is clean. 
4  If necessary, repeat steps 3a-3c until the connector is clean. 
Cleaning Bulkheads 
Important:
  Do not detach the bulkhead from the module front panel for cleaning 
under any circumstances.  There is little or no slack in the fiber attached to the 
bulkhead, and any attempt to remove the bulkhead will risk damage to the fiber. 
It is generally more difficult to clean bulkhead connectors and verify their condition 
due to the inaccessibility of the fiber end face.  For this reason, you should only 
attempt to clean a bulkhead connector when a dirty connector is indicated.