Cisco Cisco Prisma II EDR Receiver Installation Guide

Page of 184
 
 
 
Cleaning Optical Connectors 
 
78-4025693-01 Rev D 
23 
 
Follow these steps to clean the bulkhead: 
    WARNING: 
 
Avoid personal injury! Use of controls, adjustments, or performance of 
procedures other than those specified herein may result in hazardous 
radiation exposure. 
 
Avoid personal injury! The laser light source on this equipment emits 
invisible laser radiation. Avoid direct exposure to the laser light source. 
 
Avoid personal injury! Viewing the laser output with optical instruments 
(such as eye loupes, magnifiers, or microscopes) may pose an eye hazard. 
1  Insert a dry bulkhead swab into the bulkhead and rotate the swab several times. 
2  Remove the swab and discard.  Swabs may be used only once. 
3  Check the bulkhead optical surface with a fiber connector scope to confirm that it 
is clean.  If further cleaning is needed: 
a  Moisten a new bulkhead swab using a lint-free wipe moistened with optical-
grade (99%) isopropyl alcohol. 
b  With the connector removed, fully insert the bulkhead swab into the 
bulkhead and rotate the swab several times. 
c  Remove the swab and discard.  Swabs may be used only once. 
d  Check with a fiber connector scope again to confirm that there is no dirt or 
alcohol residue on the optical surface. 
e  If any alcohol residue remains, clean it off with a new dry bulkhead swab. 
4  Mate all connectors to bulkheads and proceed to Verifying Equipment 
Operation below. 
5  It is also recommended that all connectors be visually inspected after cleaning to 
verify the connector is clean and undamaged. 
Verifying Equipment Operation 
Perform circuit turn-up.  If the equipment does not come up, i.e., fails verification or 
indicates a reflection problem, clean the connectors and bulkheads again. 
For Further Assistance 
If you have any questions or concerns about cleaning fiber optic connectors, contact 
Cisco Services.