Cisco Cisco Unified Service Monitor 8.6 Release Notes

Page of 6
 
4
Release Notes for Cisco Unified Service Monitor 8.6
OL-25605-01
  Resolved Problems
Resolved Problems
 describes problems that were fixed in this release.
Note
To obtain more information about resolved problems, access the Cisco Software Bug Toolkit at 
. (You will be prompted to 
log into Cisco.com).
Obtaining Documentation and Submitting a Service Request
For information on obtaining documentation, submitting a service request, and gathering additional 
information, see the monthly What’s New in Cisco Product Documentation, which also lists all new and 
revised Cisco technical documentation, at:
Subscribe to the What’s New in Cisco Product Documentation as a Really Simple Syndication (RSS) feed 
and set content to be delivered directly to your desktop using a reader application. The RSS feeds are a free 
service and Cisco currently supports RSS Version 2.0.
Table 4
Problems Resolved in Service Monitor 
Bug ID
Summary
Explanation
CSCtl93955 
Clusters in Operations Manager 
did not initially appear in Service 
Monitor.
When Operations Manager and Service Monitor were set up in a 
master-slave configuration where Operations Manager was the master 
and Service Monitor was the slave, the clusters in Operations Manager 
did not show up in Service Monitor, initially. This problem has been 
resolved.
CSCtr11122
Unity Voicemail was missing 
from Call Category drop-down 
menu.
When you added the dial plan configuration, the categories that were 
listed did not include the Unity Voicemail category. Because of this you 
were not able to configure a pattern to get it classified under this 
category. This problem has been resolved.
CSCto93277
Out of Memory error occurred 
when the QOVR process tried to 
process any device named 
NoDevice
 in CDR entries.
Out of Memory error for the QOVR process occurred if 
NoDevice
 entries 
occurred too frequently in a CDR file. Cisco Unified Communications 
Manager created CDRs with 
NoDevice
 as the device name due to 
incorrect configuration of end points, switches, or voice gateways in a 
cluster. This problem has been resolved.
CSCto58634
In ACS Mode, Service Monitor 
does not display most of the menu 
items.
In both coresidence and coexistence modes, Service Monitor menu items 
were not displayed in ACS mode. This problem has been resolved. 
CSCtn76586
Most-Impacted Endpoints report 
for CVTQ reported very low 
Average MOS scores.
The Average MOS calculation included short duration calls for which 
there were no MOS scores. This problem has been resolved.