Cisco Cisco TelePresence MCU 4510 Release Notes

Page of 17
 
Resolved issues 
Cisco TelePresence MCU 4.3(2.30) Software Release Notes 
Page 7 of 17 
Identifier 
Description 
Template page of the MCU web user-interface when a localization package was uploaded on the 
MCU. This has been resolved in this release. 
CSCty13904  In previous 4.3 releases, when a localization package was uploaded on the MCU web interface, some 
of the fields were not displayed correctly. This has been resolved in this release. 
CSCty22375  In previous releases, when a participant.remove API command was sent immediately after a 
participant.disconnect API command, the MCU would not successfully remove the participant from 
the participant list. This has been resolved in this release. 
Resolved since 4.2(1.50) 
 
Identifier 
Description 
CSCtt19422  In previous releases, when a SIP session was refreshed, the session version parameter in the MCU's 
SDP was not updated correctly. This caused an interoperability issue with IMS phone switch where 
the calls from MCU would disconnect. This is resolved in this release. 
CSCtx76766  In previous releases, MCU could under certain circumstances experience slow performance when 
uploading large CDR logs (>100,000 messages) to TMS. This is resolved in this release. 
CSCty98518  In previous releases, when a 2 Mbps SIP call was placed from an MCU in HD mode, the MCU 
participants page would incorrectly report the receive bandwidth as 4 Mbps instead of 2 Mbps. This is 
resolved in this release.  
CSCtq91175  In previous releases, participants added to a conference via the API would not inherit the default 
layout control value of the conference. This has been resolved in this release. 
CSCtq99800  In previous releases, the MCU did not attempt to register to the alternate gatekeeper if the primary 
gatekeeper had sent a URQ. This has been resolved in this release. 
CSCtr15071  In previous releases, if a Cisco Unified Border Element (CUBE) was in the call path between the 
MCU and an endpoint, H.239 content negotiation was not possible. This has been resolved in this 
release. 
CSCtr51282  In previous releases, under some circumstances a Polycom MGC would send content to the MCU 
that is outside the advertised capabilities of the MCU and therefore the MCU was unable to correctly 
decode it. Support for these content capabilities has been added in this release. 
CSCtr80218  In previous releases, an MCU with gatekeeper setting as required, did not send an ARQ to its H.323 
gatekeeper for an incoming call from a Microsoft Netmeeting client. This has been resolved in this 
release. 
CSCtr80312  In previous releases, the active speaker indication was not shown in certain layouts. This has been 
resolved in this release. 
CSCtr85035  In previous releases, under rare circumstances, the MCU configured with an old version of TMS 
could experience a restart if it ran out of web sessions. This has been resolved in this release.  
CSCtr93658  In previous releases, uploading an invalid SSL certificate could result in a restart of the MCU. This 
has been resolved in this release. 
CSCtu01703  In previous releases, when using a three blade MCU MSE 8510 cluster, under very rare 
circumstances some participants on a slave blade would receive black panes in their video output.