Cisco Cisco TelePresence MCU 4510 Release Notes

Page of 17
 
Open issues 
Cisco TelePresence MCU 4.3(2.30) Software Release Notes 
Page 8 of 17 
Identifier 
Description 
This has been resolved in this release. 
CSCtu04630  In Version 4.2, the MCU was using an  ephemeral port range for both TCP and UDP of 10000 to 
65535 instead of the documented range of 49152 to 65535. This has been resolved in this release. 
CSCtu19596  When a conference created via an API call (for example, by Cisco TelePresence Management Suite 
(TMS)) uses a duplicate numeric ID to that of an existing ad-hoc conference on the MCU, the MCU 
correctly stops the conference from being created and generates the following error : "Failed to 
create conference" - duplicate numeric id". However, in previous releases, this error state continued 
even after the ad-hoc conference was deleted from the MCU. This has been resolved in this release. 
CSCtw49855  In previous releases, when downloading a configuration file from the master MCU in a cluster which 
is heavily loaded with participants, in rare circumstances the slave MCUs could restart because of 
loss of contact with the master MCU. This has been resolved in this release. 
CSCtw49892  In previous releases, when attempting to join a conference using a ConferenceMe invitation link, the 
request would fail with the message: “Error: conference no longer exists” if the conference name 
included some special characters. This has been resolved in this release. 
CSCtw52422  In previous releases, under certain conditions, the Polycom Viewstation endpoint was not able to 
register to the MCU’s built-in gatekeeper, and a warning message would appear in the event log. 
This has been resolved in this release. 
CSCtw61034  In previous releases, when resuming a call to the MCU that was placed on hold by any C-series 
endpoint, other participants did not hear any audio from that endpoint. This occurred in some 
versions of the MCU Version 4.2 software release and when the RTP sequence numbers increased 
by more than 32000 on resume. This has been resolved in this release. 
CSCtw72308   In previous releases, the participant join notification text was sometimes not seen by video 
participants when an audio-only participant joined the conference. This has been resolved in this 
release. 
CSCtw95448  In previous releases, the MCU could reboot when a participant set as the focused participant for 
active streaming viewers disconnected. This has been resolved in this release. 
CSCtx00682  In previous releases, when using QuickTime player to stream the content window, QuickTime would 
fail over HTTP if "redirect http to https" was enabled. This was because the MCU would incorrectly 
redirect the streaming request from HTTP to HTTPS and QuickTime player does not support this. 
This has been resolved in this release. 
CSCtx29749  In previous releases of the MCU, when sending G.728 to an MXP based endpoint, a high-pitched 
noise was heard after approximately 30 minutes. This has been resolved in this release. 
CSCtx34673  In previous releases, under rare circumstances, the MCU 4500 could fail due to a memory address 
being read incorrectly. This issue has been resolved in this release.
 
Open issues 
The following issues apply to this version of the Cisco TelePresence MCU software: 
Identifier 
Description 
CSCty77949  When an attempt has been made to overwrite a valid auto attendant banner image with an invalid 
image, the MCU may not subsequently be able to delete the valid banner image when a user deletes 
the associated auto attendant. This can lead to a situation where all the auto attendant banner space 
is used, but the images can not be deleted 
– preventing further banner image uploads.