Alcatel-Lucent omniacces-voip gateway User Manual
VoIP Commands
Page 5-45
Command Usage
Specify T1 voice port facilities data link protocol.
Syntax Options
Remarks
To use this command, the voice daughtercard connection interface type must be set to T1 via
the
the
voice port interface type
command.
voice port facilities data link protocol
voice port <
slot/port
>
facilities data link protocol {none | ansi t1.403 | at&t 54016 | t1.403 at&t}
Definitions:
slot
slot
Specifies slot number of voice switching daughtercard installed in switching module,
(e.g.,
(e.g.,
2
).
port
Specifies physical port number on voice daughtercard, (e.g.,
1
).
none
Indicates device does not use the facilities data link.
ansi t1.403
Indicates device uses the dsx1ANSI-T1-403 facilities data link exchange recommended by
ANSI.
ANSI.
at&t 54016
Indicates device uses the dsx1ATT-54016 ESF (Extended Super Frame) facilities data link
exchange.
exchange.
t1.403 at&t
Indicates device uses the ANSI t1.403 for ESF (Extended Super Frame) facilities data link
exchange.
exchange.
♦ Syntax Notes ♦
A “no facilities data link protocol” means that the frame is
unframed.
A “no facilities data link protocol ANSI T1.403,” or “no facilities
data link protocol AT&T 54016,” or “no facilities data link proto-
col T.1403 AT&T,” means that the device does not use the facili-
tites data link protocol. The “ANSI T1.403 and AT&T 54106 and
T1.403 AT&T are ignored.
Default:
The default setting is
The default setting is
none
.
Command Examples:
voice port 2/1 facilities data link protocol none
voice port 2/2 facilities data link protocol ansi t1.403
voice port 2/3 facilities data link protocol at&t 54016
voice port 2/4 facilities data link protocol t1.403 at&t
voice port 2/2 facilities data link protocol ansi t1.403
voice port 2/3 facilities data link protocol at&t 54016
voice port 2/4 facilities data link protocol t1.403 at&t