Alcatel-Lucent omniacces-voip gateway User Manual

Page of 430
VoIP Commands
Page 5-100
Command Usage
Specify E&M immediate start time to wait before beginning digit collection.
Syntax Options
Remarks
The 
voice signaling protocol
 command must be set to the corresponding protocol type before 
any commands for E&M (Wink Start, Immediate Start, and Delay Start Signaling), and FXS/
FXO (Loop and Ground Start) commands will take effect.
voice signaling emi digit wait
voice signaling channel <
slot/port/startChannel-endChannel
 > emi digit wait <
value 
>
Definitions: 
slot
Specifies chassis slot number where VSM is installed, (e.g., 
2
).
port
Specifies physical port number on voice daughtercard, (e.g., 
1
).
startChannel
The first number in the range of voice channels (e.g., 
1
).
endChannel
The last number in the range of voice channels (e.g., 
30
). 
 Syntax Note 
Be sure to separate the start and end range numbers with a 
hyphen (e.g., 
1-30
).
value
Specifies time period, in milliseconds from 0 to 60,000, (e.g., 
200
), to wait for the voice 
daughtercard to be ready before collecting digits. The line stays off-hook and generates a 
dial tone if glare condition detected in the interim.
 Syntax Note 
Do not use commas when entering the E&M immediate start 
time value, i.e., time to wait for before digit collection is enabled 
and an off-hook congestion tone with glare condition is reported 
(for example, 
5,000
 will return a syntax error message).
Default:
The default value is 
200
 milliseconds.
Command Examples:
voice signaling channel 2/1/1-12 emi digit wait 200
voice signaling channel 2/2/13-24 emi digit wait 30000
voice signaling channel 2/3/1-30 emi digit wait 60000