Alcatel-Lucent omniacces-voip gateway User Manual
VoIP Commands
Page 5-146
Command Usage
Specify Foreign Exchange Office (FXO) Ground Start (GS) debounce interval for battery rever-
sal detector.
sal detector.
Syntax Options
Remarks
The
voice signaling protocol
command must be set to the corresponding protocol type before
any commands for E&M (Wink Start, Immediate Start, and Delay Start Signaling), and FXS/
FXO (Loop and Ground Start) commands will take effect.
FXO (Loop and Ground Start) commands will take effect.
voice signaling fxo gs battery reversal debounce
voice signaling channel <
slot/port/startChannel-endChannel
> fxo gs battery reversal debounce
<
value
>
Definitions:
slot
slot
Specifies chassis slot number where VSM is installed, (e.g.,
2
).
port
Specifies physical port number on voice daughtercard, (e.g.,
1
).
startChannel
The first number in the range of voice channels (e.g.,
1
).
endChannel
The last number in the range of voice channels (e.g.,
30
).
♦ Syntax Note ♦
Be sure to separate the start and end range numbers with a
hyphen (e.g.,
1-30
).
valueS
Specifies the time to use as a debouncer (delay interval) for debouncing the battery rever-
sal detector, in milliseconds from 1 to 1,000, (e.g.,
sal detector, in milliseconds from 1 to 1,000, (e.g.,
20
).
♦ Syntax Note ♦
Do not use commas when entering the fxs gs debounce value
for the battery reversal detector (for example,
for the battery reversal detector (for example,
1,000
will return a
syntax error message).
Default:
The default value is
The default value is
20
milliseconds.
Command Examples:
voice signaling channel 2/1/1-12 fxo gs battery reversal debounce 20
voice signaling channel 2/2/13-24 fxo gs battery reversal debounce 500
voice signaling channel 2/3/1-30 fxo gs battery reversal debounce 1000
voice signaling channel 2/2/13-24 fxo gs battery reversal debounce 500