Alcatel-Lucent omniacces-voip gateway User Manual

Page of 430
 VoIP Commands
Page 5-147
Command Usage
Set outbound caller ID name (private/unavailable) to transmit.
Syntax Options
Remarks
Caller ID time is automatically determined (read) from the system time on the switch. If the 
caller ID name or number is changed, the voice switching daughtercard is initialized with the 
time automatically.
voice signaling caller id name
voice signaling channel <
slot/port/startChannel-endChannel
 > caller id name {
“callerIdName” 
private
 
| unavailable}
Definitions:
slot
Specifies chassis slot number where VSM is installed, (e.g., 
2
).
port
Specifies physical port number on voice daughtercard, (e.g., 
1
).
startChannel
The first number in the range of voice channels (e.g., 
1
).
endChannel
The last number in the range of voice channels (e.g., 
30
). 
 Syntax Note 
Be sure to separate the start and end range numbers with a 
hyphen (e.g., 
1-30
).
callerIdName
Identifies the caller by name, (e.g., 
“gleneck_daniel”
); maximum length of 15 characters. 
The following characters are permitted in the caller ID name: a-z, A-Z, _ , and no spaces 
are allowed. Name must be surrounded by quotes.
private
Sets outbound originating caller ID name that transmits to “private” (may be abbreviated to 
“p”).
unavailable
Sets outbound originating caller ID name that transmits to “unavailable” (may be abbrevi-
ate to “o”).
 Syntax Note 
The 
voice coding profile caller id 
command must be enabled to 
use this command.
Default:
The default setting is 
private
.
Command Examples:
voice signaling channel 2/1/1-12 caller id name “vernell_b”
voice signaling channel 2/1/1-12 caller id name private
voice signaling channel 2/2/13-24 caller id name unavailable
voice signaling channel 4/2/1-1 caller id name “p”